Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35.019
Filtrar
1.
Cancer Imaging ; 24(1): 46, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556864

RESUMO

BACKGROUND: PSMA PET/CT is the most sensitive molecular imaging modality for prostate cancer (PCa), yet much of the developing world has little or no access to PET/CT. [99mTc]Tc-PSMA scintigraphy (PS) is a cheaper and more accessible gamma camera-based alternative. However, many resource-constrained departments have only a single camera without tomographic or hybrid imaging functionality, and camera time is frequently in high demand. Simplifying imaging protocols by limiting the field of view (FOV) and omitting SPECT/CT or even SPECT may provide a partial solution. The aim was thus to determine the adequacy of PS planar-only and/or SPECT-only imaging protocols with a limited FOV. METHODS: The scans of 95 patients with histologically proven PCa who underwent PS with full-body planar and multi-FOV SPECT/CT were reviewed. The detection rates for uptake in the prostate gland/bed and in metastases were compared on planar, SPECT, and SPECT/CT. The agreement between modalities was calculated for the detection of metastases and for staging. The impact of imaging a limited FOV was determined. RESULTS: Pathological prostatic uptake was seen in all cases on SPECT/CT (excluding two post-prostatectomy patients), 90.3% of cases on SPECT, and 15.1% on planar images (p < 0.001). Eleven (11.7%) patients had seminal vesicle involvement on SPECT/CT, which was undetectable/indistinguishable on planar images and SPECT. The agreement between modalities was moderate to good (κ = 0.41 to 0.61) for the detection of nodal metastases, with detection rates that did not differ significantly (SPECT/CT = 11.6%, SPECT = 8.4%, planar = 5.3%). Detection rates for bone metastases were 14.7% (SPECT/CT) and 11.6% (SPECT and planar). Agreement between modalities for the detection of bone metastases was good (κ = 0.73 to 0.77). Three (3.1%) patients had visceral metastases on SPECT/CT, two of which were detected on SPECT and planar. There was good agreement between modalities for the TNM staging of patients (κ = 0.70 to 0.88). No metastatic lesions were missed on the limited FOV images. CONCLUSION: When PS scintigraphy is performed, SPECT/CT is recommended. However, the lack of SPECT/CT capabilities should not preclude the use of PS in the presence of limited resources, as both planar and SPECT imaging are adequate and will correctly stage most PCa patients. Furthermore, time-based optimisations are achievable by limiting the FOV to exclude the distal lower limbs.


Assuntos
Neoplasias Ósseas , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Região de Recursos Limitados , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias Ósseas/secundário
2.
PLoS One ; 19(4): e0301978, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603674

RESUMO

Radiomic features are usually used to predict target variables such as the absence or presence of a disease, treatment response, or time to symptom progression. One of the potential clinical applications is in patients with Parkinson's disease. Robust radiomic features for this specific imaging method have not yet been identified, which is necessary for proper feature selection. Thus, we are assessing the robustness of radiomic features in dopamine transporter imaging (DaT). For this study, we made an anthropomorphic head phantom with tissue heterogeneity using a personal 3D printer (polylactide 82% infill); the bone was subsequently reproduced with plaster. A surgical cotton ball with radiotracer (123I-ioflupane) was inserted. Scans were performed on the two-detector hybrid camera with acquisition parameters corresponding to international guidelines for DaT single photon emission tomography (SPECT). Reconstruction of SPECT was performed on a clinical workstation with iterative algorithms. Open-source LifeX software was used to extract 134 radiomic features. Statistical analysis was made in RStudio using the intraclass correlation coefficient (ICC) and coefficient of variation (COV). Overall, radiomic features in different reconstruction parameters showed a moderate reproducibility rate (ICC = 0.636, p <0.01). Assessment of ICC and COV within CT attenuation correction (CTAC) and non-attenuation correction (NAC) groups and within particular feature classes showed an excellent reproducibility rate (ICC > 0.9, p < 0.01), except for an intensity-based NAC group, where radiomic features showed a good repeatability rate (ICC = 0.893, p <0.01). By our results, CTAC becomes the main threat to feature stability. However, many radiomic features were sensitive to the selected reconstruction algorithm irrespectively to the attenuation correction. Radiomic features extracted from DaT-SPECT showed moderate to excellent reproducibility rates. These results make them suitable for clinical practice and human studies, but awareness of feature selection should be held, as some radiomic features are more robust than others.


Assuntos
Proteínas da Membrana Plasmática de Transporte de Dopamina , Nortropanos , 60570 , Humanos , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Computadores
3.
PLoS One ; 19(4): e0300466, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38626058

RESUMO

Pretargeting, which is the separation of target accumulation and the administration of a secondary imaging agent into two sequential steps, offers the potential to improve image contrast and reduce radiation burden for nuclear imaging. In recent years, the tetrazine ligation has emerged as a promising approach to facilitate covalent pretargeted imaging due to its unprecedented kinetics and bioorthogonality. Pretargeted bone imaging with TCO-modified alendronic acid (Aln-TCO) is an attractive model that allows the evaluation of tetrazines in healthy animals without the need for complex disease models or targeting regimens. Recent structure-activity relationship studies of tetrazines evaluated important parameters for the design of potent tetrazine-radiotracers for pretargeted imaging. However, limited information is available for 99mTc-labeled tetrazines. In this study, four tetrazines intended for labeling with fac-[99mTc(OH2)3 (CO)3]+ were synthesized and evaluated using an Aln-TCO mouse model. 3,6-bis(2-pyridyl)-1,2,4,5-Tz without additional linker showed higher pretargeted bone uptake and less background activity compared to the same scaffold with a PEG8 linker or 3-phenyl-1,2,4,5-Tz-based compounds. Additionally, improved bone/blood ratios were observed in pretargeted animals compared to animals receiving directly labeled Aln-TCO. The results of this study implicate 3,6-bis(2-pyridyl)-1,2,4,5-Tz as a promising scaffold for potential 99mTc-labeled tetrazines.


Assuntos
Compostos Heterocíclicos , Tomografia Computadorizada por Raios X , Animais , Camundongos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Linhagem Celular Tumoral , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons/métodos
4.
PLoS One ; 19(4): e0301756, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578730

RESUMO

INTRODUCTION: Amyloid deposition is a cause of restrictive cardiomyopathy. Patients who present with cardiac disease can be evaluated for transthyretin (TTR)-associated cardiac amyloidosis using nuclear imaging with 99mTc-labeled pyrophosphate (PYP); however, light chain-associated (AL) cardiac amyloid is generally not detected using this tracer. As an alternative, the amyloid-binding peptide p5+14 radiolabeled with iodine-124 has been shown to be an effective pan-amyloid radiotracer for PET/CT imaging. Here, a 99mTc-labeled form of p5+14 peptide has been prepared to facilitate SPECT/CT imaging of cardiac amyloidosis. METHOD: A synthesis method suitable for clinical applications has been used to prepare 99mTc-labeled p5+14 and tested for peptide purity, product bioactivity, radiochemical purity and stability. The product was compared with99mTc-PYP for cardiac SPECT/CT imaging in a mouse model of AA amyloidosis and for reactivity with human tissue sections from AL and TTR patients. RESULTS: The 99mTc p5+14 tracer was produced with >95% yields in radiopurity and bioactivity with no purification steps required and retained over 95% peptide purity and >90% bioactivity for >3 h. In mice, the tracer detected hepatosplenic AA amyloid as well as heart deposits with uptake ~5 fold higher than 99mTc-PYP. 99mTc p5+14 effectively bound human amyloid deposits in the liver, kidney and both AL- and ATTR cardiac amyloid in tissue sections in which 99mTc-PYP binding was not detectable. CONCLUSION: 99mTc-p5+14 was prepared in minutes in >20 mCi doses with good performance in preclinical studies making it suitable for clinical SPECT/CT imaging of cardiac amyloidosis.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Camundongos , Animais , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Amiloidose/diagnóstico por imagem , Amiloidose/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Peptídeos , Amiloide/metabolismo , Cardiomiopatias/diagnóstico por imagem , Pré-Albumina
5.
J Mater Chem B ; 12(15): 3659-3675, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38530751

RESUMO

The demand for tailored, disease-adapted, and easily accessible radiopharmaceuticals is one of the most persistent challenges in nuclear imaging precision medicine. The aim of this work was to develop two multimodal radiotracers applicable for both SPECT and PET techniques, which consist of a gold nanoparticle core, a shell involved in radioisotope entrapment, peripherally placed targeting molecules, and biocompatibilizing polymeric sequences. Shell decoration with glucosamine units located in sterically hindered molecular environments is expected to result in nanoparticle accumulation in high-glucose-consuming areas. Gold cores were synthesized using the Turkevich method, followed by citrate substitution with linear PEG α,ω-functionalized with thiol and amine groups. The free amine groups facilitated the binding of branched polyethyleneimine through an epoxy ring-opening reaction by using PEG α,ω-diglycidyl ether as a linker. Afterwards, the glucose-PEG-epoxy prepolymer has been grafted onto the surface of AuPEG-PEI conjugates. Finally, the AuPEG-PEI-GA conjugates were radiolabeled with 99mTc or 68Ga. Instant thin-layer chromatography was used to evaluate the radiolabeling yield. The biocompatibility of non-labeled and 99mTc or 68Ga labeled nanoparticles was assessed on normal fibroblasts. The 99mTc complexes remained stable for over 22 hours, while the 68Ga containing ones revealed a slight decrease in stability after 1 hour.


Assuntos
Ouro , Nanopartículas Metálicas , Ouro/química , Radioisótopos de Gálio , Nanopartículas Metálicas/química , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia por Emissão de Pósitrons , Glucose , Aminas
6.
Phys Med Biol ; 69(9)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38537308

RESUMO

Objective.A Monte Carlo virtual source model named PHID (photon from Ion decay) that generates photons emitted in the complex decay chain process of alpha-emitter radionuclides is proposed, typically for use during the simulation of SPECT image acquisition.Approach.Given an alpha-emitter radionuclide, the PHID model extracts from Geant4 databases the photon emission lines from all decaying daughters for both isometric transition and atomic relaxation processes. According to a given time range, abundances and activities in the decay chain are considered thanks to the Bateman equations, taking into account the decay rates and the initial abundances.Main results.PHID is evaluated by comparison with analog Monte Carlo simulation. It generates photons with the correct energy and temporal distribution, avoiding the costly simulation of the complete decay chain thus decreasing the computation time. The exact time gain depends on the simulation setup. As an example, it is 30× faster for simulating 1 MBq of225Ac in water for 1 section Moreover, for225Ac, PHID was also compared to a simplified source model with the two main photon emission lines (218 and 440 keV). PHID shows that 2 times more particles are simulated and 60% more counts are detected in the images.Significance.PHID can simulate any alpha-emitter radionuclide available in the Geant4 database. As a limitation, photons emitted from Bremsstrahlung are ignored, but they represent only 0.7% of the photons above 30 keV and are not significant for SPECT imaging. PHID is open-source, available in GATE 10, and eases the investigation of imaging photon emission from alpha emitters.


Assuntos
Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Fótons , Imagens de Fantasmas , Método de Monte Carlo
7.
Mol Imaging Biol ; 26(2): 264-271, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38441862

RESUMO

PURPOSE: The current established technique for sentinel lymph node (SLN) biopsy is preoperative injection of 99mtechnetium-labeled nanosized colloids (99mTc) followed by single photon emission computed tomography and standard computed tomography (SPECT/CT) with subsequent intraoperative gamma probe-guided excision of the SLN. It is however time and resource consuming, causes radiation exposure and morbidity for the patient as the injection is done in the awake patient. Recently near-infrared imaging with indocyanine green (ICG) gained importance in SLN biopsy as a faster and more convenient technique. The objective of our study was to investigate the feasibility of SLN biopsy using ICG-imaging in early oral squamous cell carcinoma (OSCC). METHODS: Single-centre pilot study of five patients with early-stage OSCC. For all patients, both techniques (99mTc and ICG) were performed. We injected 99mTc preoperatively in the awake patient, followed by SPECT/CT imaging. Intraoperatively ICG was injected around the primary tumor. Then the neck incision was performed according to the SPECT/CT images and SLN were detected by using a gamma probe and near-infrared fluorescence imaging of the ICG-marked lymph nodes intraoperatively. The excised lymph nodes were sent to histopathological examination according to the SLN dissection protocol. RESULTS: In all five patients sentinel lymph nodes were identified. A total of 7 SLN were identified after injection of 99mTc, imaging with SPECT/CT and intraoperative use of a gamma probe. All these SLN were fluorescent and visible with the ICG technique. In two patients, we could identify additional lymph nodes using the ICG technique. Pathological analysis demonstrated occult metastasis in two of the cases. CONCLUSIONS: Our study shows that ICG-guided SLN biopsy is a feasible technique, especially in combination with conventional radioisotope method and may help for intraoperative localization of SLN. Validation studies with bigger patient cohorts are needed to prove our results.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Humanos , Biópsia de Linfonodo Sentinela/métodos , Verde de Indocianina , Projetos Piloto , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Linfonodos/patologia , Corantes , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias de Cabeça e Pescoço/patologia
8.
Clin Neurol Neurosurg ; 239: 108180, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38452713

RESUMO

OBJECTIVE: Few studies have reported local hemodynamic changes after revascularization surgery. This study aimed to identify regional hemodynamic changes after combined revascularization surgery for moyamoya disease using single-photon emission computed tomography with N-isopropyl-p-123I-iodoamphetamine. METHODS: A total of 46 adults with moyamoya disease who underwent combined revascularization surgery from August 2009 to July 2021 at our facility were enrolled. The combined bypass procedure comprised a single direct bypass to the motor area and encephalo-duro-arterio-myo-synangiosis. The preoperative and postoperative cerebral blood flow (CBF) and cerebral vascular reserve (CVR) in the genu; precentral, central, parietal, angular, temporal, and posterior regions; splenium; hippocampus; and cerebellum were measured. To modify the examination variability, the cerebral-to-cerebellar activity ratio (CCR) was calculated by dividing the counts in the region by those in the cerebellum (CBF-CCR and CVR-CCR). RESULTS: Postoperatively, asymptomatic cerebral infarction occurred in three (6.5%) patients. The CBF-CCR and CVR-CCR improved in the precentral, parietal, and temporal regions and in the overall middle cerebral artery (MCA) territory. Sub-analysis of anterior cerebral artery (ACA) and posterior cerebral artery (PCA) territory hemodynamics revealed that patients with normal preoperative hemodynamics showed no changes in the CBF-CCR and CVR-CCR postoperatively, whereas patients with preoperative perfusion impairment exhibited improved CVR-CCR in the ACA territory (0.13-0.3, p=0.019) and CBF-CCR in the PCA territory (0.93-0.96, p=0.0039). CONCLUSION: Combined revascularization surgery with single bypass to the motor area improved hemodynamics in the primary targeted MCA territory and in the ACA and PCA territories among patients with preoperative hemodynamic impairment.


Assuntos
Revascularização Cerebral , Doença de Moyamoya , Adulto , Humanos , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único , Artéria Cerebral Anterior/cirurgia , Artéria Cerebral Média/cirurgia , Circulação Cerebrovascular/fisiologia , Revascularização Cerebral/métodos , Hemodinâmica
9.
Sci Rep ; 14(1): 6624, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503852

RESUMO

We investigated the feasibility of using a dopamine transporter (DaT) tracer ligand ([123I]FP-CIT) along with novel multi-pinhole brain collimators for dynamic brain single photon emission computed tomography (SPECT) in suspected Parkinson's disease patients. Thirteen patients underwent dynamic tracer acquisitions before standard imaging. Uptake values were corrected for partial volume effects. Specific binding ratio (SBRcalc) was calculated, reflecting binding potential relative to non-displaceable binding (BPND) in the cortex. Additional pharmacokinetic parameters (BPND, R1, k2) were estimated using the simplified reference tissue model, revealing differences between Kahraman low-score (LS) and high-score (HS) groups. Results showed increasing striatal tracer uptake until 100 min post-injection, with consistent values afterward. Uptake and SBRcalc ratios matched visual assessment. LS patients had lower putamen than caudate nucleus tracer uptake, decreased BPND values, while R1 and k2 values were comparable to HS patients. In conclusion, dynamic multi-pinhole SPECT using DaT tracer with the extraction of pharmacokinetic parameters is feasible and could help enable early differentiation of reduced and normal DaT values.


Assuntos
Doença de Parkinson , Humanos , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/metabolismo , Estudos de Viabilidade , Tropanos/metabolismo , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Putamen/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo
10.
Front Endocrinol (Lausanne) ; 15: 1359655, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487344

RESUMO

Objective: There is currently no non-invasive examination that can fully determine the diagnosis of osteomyelitis. SPECT/CT tomographic fusion imaging can provide both local metabolic activity and anatomical information to determine the condition and location. This study evaluates the diagnostic efficacy of 99mTc-MDP SPECT/CT in bone infections, compared to MRI. Methods: In this multicenter retrospective study, 363 patients with suspected bone and joint infections or osteomyelitis were included. Participants underwent 99mTc-MDP SPECT/CT and/or MRI examinations, supplemented by pathogenic bacterial cultures and histopathological analysis. Results: Only SPECT/CT was tested in 169 patients, and only MRI was used in 116. 78 people have implemented both inspections and have detailed information. The diagnostic sensitivity and specificity of SPECT/CT for infection were 96% and 92% respectively, with an accuracy of 96%. For MRI, these figures were 88%, 84%, and 87% respectively. Conclusion: This represents the largest global study to date evaluating osteomyelitis and bone infection diagnosis using 99mTc-MDP SPECT/CT tomographic fusion imaging. The findings indicate that 99mTc-MDP SPECT/CT fusion imaging offers superior diagnostic accuracy compared to MRI. This is particularly evident in cases involving metallic implants and chronic infections. 99mTc-MDP SPECT/CT fusion imaging emerges as a highly suitable non-invasive diagnostic modality, facilitating enhanced clinical follow-up and treatment.


Assuntos
Difosfatos , Osteomielite , Humanos , Estudos Retrospectivos , Medronato de Tecnécio Tc 99m , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Imageamento por Ressonância Magnética , Osteomielite/diagnóstico por imagem
11.
Nucl Med Rev Cent East Eur ; 27(0): 1-5, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38529769

RESUMO

BACKGROUND: Nuclear medicine uses radionuclides in medicine for diagnosis, staging, therapy, and monitoring the response to therapy. The application of radiopharmaceutical therapy for the treatment of certain diseases is well-established, and the field is expanding. Internal dosimetry is multifaceted and includes different workflows, as well as various calculations based on patient- specific dosimetry. AIM: The objective of this study was to introduce the technical issues which might occur during iodine-131 (¹³¹I) dosimetry performed in nuclear medicine departments. MATERIAL AND METHODS: Retrospective analysis was performed on a group of 44 patients with papillary thyroid cancer who between May 2021 and October 2021 underwent a 131I treatment: 80-100 mCi (2200-3700 MBq, based on the previous medical history and stage of the disease). Patients underwent a series of ¹³¹I therapy scans using gamma camera Discovery NM 670 CT. Whole body scan (WBS) was performed 2, 4, 24 and 48 hours after ¹³¹I administration. Additionally, after 24 hours of single photon emission computed tomography/ computed tomography, two fields of view (SPECT/CT 2-FOV) were performed from the mid-head to the bladder. RESULTS: During the dosimetry procedure, several issues arise. Firstly, after receiving therapeutic doses of ¹³¹I, patients should remain in their rooms until the appropriate activity is achieved before being transported to the diagnostic room. Secondly, the walls between examination rooms meet the requirements for accurate diagnosis but not for therapy, leading to the occurrence of artefacts in patients examined behind the wall, potentially influencing the examination results. Thirdly, personnel in the control room also experience additional exposure (10 times greater than in the case of standard diagnostic procedure). CONCLUSIONS: The dosimetry in patients in whom therapeutic procedures are performed with the use of isotopes is mandatory according to Polish and European law, technical issues which occur during the dosimetry procedures might influence the organization of the work in departments.


Assuntos
Radioisótopos do Iodo , Neoplasias da Glândula Tireoide , Humanos , Radioisótopos do Iodo/uso terapêutico , Estudos Retrospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia
12.
BMC Oral Health ; 24(1): 305, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443942

RESUMO

BACKGROUND: The long time required for bone uptake of radiopharmaceutical material after injection for bone scintigraphy is a burden for patients with poor health. Thus, to assess whether the uptake time could be reduced for single-photon emission computed tomography (SPECT) of the jawbone, this study evaluated differences in maximum standardized uptake values (SUVmax) within patients using SPECT imaging at 2 and 3 hours after radiopharmaceutical injection. METHODS: A total of 33 patients undergoing treatment or in post-treatment follow-up for medication-related osteonecrosis of the jaw, who visited our hospital between July 2020 and August 2021 and could receive SPECT twice on the same day, were enrolled in the study. Patients were injected with technetium-99 m hydroxymethylene diphosphonate (Tc-99 m HMDP) intravenously. The SUVmax for healthy parietal bones and jawbone lesions were calculated from the SPECT images using quantitative analysis software, and the SUVmax were compared between 2- and 3-hour uptake times. RESULTS: After exclusion, 30 patients were included in the study. In the 2-hour and 3-hour images, the median SUVmax of the parietal bones were 1.90 and 1.81, respectively, and those of the jawbone lesions were 9.25 and 9.39, respectively. The limits of agreement (LOA) ranged from - 0.33 to 0.25 in the parietal bones, and the %LOA ranged from - 9.8 to 17.3% in the jawbone lesions, showing high equivalence between the two uptake durations. The SUVmax showed no clinical differences between the 2- and 3-hour uptake durations for Tc-99 m HMDP SPECT of the jawbone. CONCLUSIONS: The results of this study justify a 2-3-hour uptake window when performing quantitative SPECT of the jawbone. Therefore, the minimum uptake time can potentially be reduced to only 2 hours.


Assuntos
Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Estudos Transversais , Difosfonatos
13.
Sci Rep ; 14(1): 5492, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448648

RESUMO

This study compared computational fluid dynamic (CFD) model predictions on aerosol deposition in six asthmatic patients to the in-vivo results of the same group. Patient-specific ventilation and internal air distribution were prescribed using inspiratory and expiratory CT scans of each patient, accounting for individual lobar air flow distribution. Moreover, the significant influence of realistic mouth and throat geometries on regional deposition is demonstrated. The in-vivo data were obtained from single photon emission computed tomography (SPECT) in 6 subjects with mild asthma selected from a database of historical clinical trials. The governing flow and particle tracking equations were solved numerically using a commercial CFD tool, and the modeled deposition results were compared to the SPECT data. Good agreement was found between the CFD model, applying k-ω SST turbulence model, and SPECT in terms of aerosol deposition. The average difference for the lobar deposition obtained from CFD model and SPECT/CT data was 2.1%. The high level of agreement is due to applying patient specific airway geometries and inspiratory/expiratory CT images, anatomical upper airways, and realistic airway trees. The results of this study show that CFD is a powerful tool to simulate patient-specific deposition if correct boundary conditions are applied and can generate similar information obtained with functional imaging tools, such as SPECT.


Assuntos
Asma , Laringe , Humanos , Hidrodinâmica , Tomografia Computadorizada de Emissão de Fóton Único , Nariz , Asma/diagnóstico por imagem , Aerossóis e Gotículas Respiratórios
14.
Contrast Media Mol Imaging ; 2024: 5453692, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38435483

RESUMO

Purpose: Ovarian cancer in the early stage requires a complete surgical staging, including radical lymphadenectomy, implying subsequent risk of morbidity and complications. Sentinel lymph node (SLN) mapping is a procedure that attempts to reduce radical lymphadenectomy-related complications and morbidities. Our study evaluates the feasibility of SLN mapping in patients with ovarian tumors by the use of intraoperative Technetium-99m-Phytate (Tc-99m-Phytate) and postoperative lymphoscintigraphy using tomographic (single-photon emission computed tomography/computed tomography (SPECT/CT)) acquisition. Materials and Methods: Thirty-two patients with ovarian mass participated in this study. Intraoperative injection of the radiopharmaceutical was performed just after laparotomy and before the removal of tumor in utero-ovarian and suspensory ligaments of the ovary just beneath the peritoneum. Subsequently, pelvic and para-aortic lymphadenectomy was performed for malignant masses, and the presence of tumor in the lymph nodes was assessed through histopathological examination. Conversely, lymphadenectomy was not performed in patients with benign lesions or borderline ovarian tumors. Lymphoscintigraphy was performed within 24 hr using tomographic acquisition (SPECT/CT) of the abdomen and pelvis. Results: Final pathological examination showed 19 patients with benign pathology, 5 with borderline tumors, and 6 with malignant ovarian tumors. SPECT/CT identified SLNs in para-aortic-only areas in 6 (20%), pelvic/para-aortic areas in 14 (47%), and pelvic-only areas in 7 (23%) cases. Notably, additional unusual SLN locations were revealed in perirenal, intergluteal, and posterior to psoas muscle regions in three patients. We were not able to calculate the false negative rate due to the absence of patients with involved lymph nodes. Conclusion: SLN mapping using intraoperative injection of radiotracers is safe and feasible. Larger studies with more malignant cases are needed to better evaluate the sensitivity of this method for lymphatic staging of ovarian malignancies.


Assuntos
Linfocintigrafia , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
15.
Yakugaku Zasshi ; 144(3): 285-290, 2024.
Artigo em Japonês | MEDLINE | ID: mdl-38432938

RESUMO

Many useful radionuclides exist among the halogen elements. Fluorine-18 (18F) is used for positron emission tomography (PET) diagnosis, iodine-123 and iodine-131 (131I) for single photon emission computed tomography (SPECT) diagnosis, 131I for nuclear medicine therapy, and iodine-125 (125I) for research. Astatine-211 (211At), which can be produced by a cyclotron and is attracting attention as a versatile α-ray emitting radionuclide, also belongs to the halogen family. Therefore, if a labeling agent that can stably hold radio-halogens can be developed, it would be useful for the development of radiotheranostic agents that can be expanded from nuclear medicine diagnosis using PET and SPECT to nuclear medicine therapy using ß--rays and even α-rays. Currently, benzoic acid derivatives are widely used as labeling agents for radio-halogens. The compounds labeled with 18F or radioiodine using this structure retain the radionuclide stably in vivo, but when 211At is labeled using this structure, 211At is rapidly released from the structure in vivo. Therefore, it is desirable to develop labeling agents that can stably hold 18F to 211At. Under these circumstances, we have found that a neopentyl structure with diol can stably retain 211At and 125I in vivo. Furthermore, this structure can also stably retain 18F in vivo. In this review, I would like to introduce the characteristics of neopentyl diol as a radio-halogens labeling agent and the development of radiotheranositc agents using neopentyl diol.


Assuntos
Radioisótopos do Iodo , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Halogênios
16.
Eur J Med Chem ; 270: 116349, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38555856

RESUMO

Serotonergic (5-hydroxytryptamine; 5-HT) receptors play critical roles in neurological and psychological disorders such as schizophrenia, anxiety, depression, and Alzheimer's diseases. Therefore, it is particularly important to develop novel radioligands or modify the existing ones to identify the serotonergic receptors involved in psychiatric disorders. Among the 16 subtypes of serotonergic systems, only technetium-99m based radiopharmaceuticals have been evaluated for serotonin-1A (5-HT1A), serotonin-2A (5-HT2A), 5-HT1A/7 heterodimers and serotonin receptor neurotransmitter (SERT). This review focuses on recent efforts in the design, synthesis and evaluation of 99mTc-radioligands used for single photon emission computerized tomography (SPECT) imaging of serotonergic (5-HT) receptors. Additionally, the discussion will cover aspects such as chemical structure, in vitro/vivo stability, affinity toward serotonin receptors, blood-brain barrier permeation (BBB), and biodistribution study.


Assuntos
Encéfalo , Serotonina , Humanos , Encéfalo/metabolismo , Distribuição Tecidual , Barreira Hematoencefálica/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Compostos Radiofarmacêuticos/química , Tecnécio/química , Receptores de Serotonina/metabolismo
17.
Phys Med ; 120: 103335, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38555793

RESUMO

PURPOSE: The aim was to investigate the use of multiple small VOIs for kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy. METHOD: The study was based on patient and simulated SPECT images in anthropomorphic geometries. Images were reconstructed using two reconstruction programs (local LundaDose and commercial Hermia) using OS-EM with and without resolution recovery (RR). Five small VOIs were placed to determine the average activity concentration (AC) in each kidney. The study consisted of three steps: (i) determination of the number of iterations for AC convergence based on simulated images; (ii) determination of recovery-coefficients (RCs) for 2 mL VOIs using a separate set of simulated images; (iii) assessment of operator variability in AC estimates for simulated and patient images. Five operators placed the VOIs, using for guidance: a) SPECT/CT with RR, b) SPECT/CT without RR, and c) CT only. For simulated images, time-integrated ACs (TIACs) were evaluated. For patient images, estimated ACs were compared with results of a previous method based on whole-kidney VOIs. RESULTS: Eight iterations and ten subsets were sufficient for both programs and reconstruction settings. Mean RCs (mean ± SD) with RR were 1.03 ± 0.02 (LundaDose) and 1.10 ± 0.03 (Hermia), and without RR 0.91 ± 0.03 (LundaDose) and 0.94 ± 0.03 (Hermia). Most stable and accurate estimates of the AC were obtained using five 2-mL VOIs guided by SPECT/CT with RR, applying them to images without RR, and including an explicit RC for recovery correction. CONCLUSION: The small VOI method based on five 2-mL VOIs was found efficient and sufficiently accurate for kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy.


Assuntos
Compostos Heterocíclicos com 1 Anel , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Rim
18.
ACS Appl Bio Mater ; 7(4): 2354-2366, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38481091

RESUMO

This work reports an "all-in-one" theranostic upconversion luminescence (UCL) system having potential for both diagnostic and therapeutic applications. Despite considerable efforts in designing upconversion nanoparticles (UCNPs) for multimodal imaging and tumor therapy, there are few reports investigating dual modality SPECT/optical imaging for theranostics. Especially, research focusing on in vivo biodistribution studies of intrinsically radiolabeled UCNPs after intravenous injection is of utmost importance for the potential clinical translation of such formulations. Here, we utilized the gamma emission from 169Er and 171Er radionuclides for the demonstration of radiolabeled ZnAl2O4:171/169Er3+ as a potent agent for dual-modality SPECT/optical imaging. No uptake of radio nanoformulation was detected in the skeleton after 4 h of administration, which evidenced the robust integrity of ZnAl2O4:169/171Er3+. Combining the therapeutics using the emission of ß- particulates from 169Er and 171Er will be promising for the radio-theranostic application of the synthesized ZnAl2O4:169/171Er3+ nanoformulation. Cell toxicity studies of ZnAl2O4:1%Er3+ nanoparticles were examined by an MTT assay in B16F10 mouse melanoma cell lines, which demonstrated good biocompatibility. In addition, we explored the mechanism of UCL modulation via defect engineering by Bi3+ codoping in the ZnAl2O4:Er3+ upconversion nanophosphor. The UCL color tuning was successfully achieved from the red to the green region as a function of Bi3+ codoping concentrations. Further, we tried to establish a correlation of UCL tuning with the intrinsic oxygen and cation vacancy defects as a function of Bi3+ codoping concentrations with the help of electron paramagnetic resonance (EPR) and positron annihilation lifetime spectroscopy (PALS) studies. This study contributes to building a bridge between nature of defects and UC luminescence that is crucial for the design of advanced UCNPs for theranostics.


Assuntos
Luminescência , Nanopartículas , Animais , Camundongos , Nanopartículas/química , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
20.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38472038

RESUMO

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Assuntos
Infecções Cardiovasculares , Endocardite , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Consenso , Tomografia Computadorizada por Raios X , Imagem Multimodal , Endocardite/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...